ANALISIS PENGGUNAAN NGR (NEUTRAL GROUNDING RESISTOR) UNTUK MEREDUKSI ARUS GROUND FAULT PADA TRANSFORMATOR GARDU INDUK SUKOREJO PASURUAN

Riszaldi, Moch Ajie (2018) ANALISIS PENGGUNAAN NGR (NEUTRAL GROUNDING RESISTOR) UNTUK MEREDUKSI ARUS GROUND FAULT PADA TRANSFORMATOR GARDU INDUK SUKOREJO PASURUAN. Skripsi thesis, Institut Teknologi Nasional Malang.

[img] Text
18. File Lengkap Skripsi.pdf
Restricted to Registered users only
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (2MB) | Request a copy

Abstract

Analisis Penggunaan NGR (Neutral Grounding Resistor) Untuk Mereduksi Arus Ground Fauld Pada Transformator Gardu Induk Sukorejo Pasuruan Moch Ajie Riszaldi I Made Wartana majieriszaldi@gmail.com Abstrak Tingginya arus gangguan hubung singkat dapat membahayakan transformator dan makluk hidup pada area Gardu Induk, oleh karena itu diperlukan petanahan NGR (Neutral Grounding Resistor) untuk mereduksi arus hubung singkat agar tegangan sentuh dan tegangan langkah tidak melebihi batas yang diizinkan sesuai dengan standart IEEE 80 tahun 2000. Dengan Metode penggunaan sistem pentanahan NGR (Neutral Grounding Resistor) arus gangguan hubung singkat satu fasa ke tanah, dua fasa ketanah dan tiga fasa dapat di reduksi dengan menentukan nilai resistance NGR, sehingga arus gangguan tidak melebihi standart yang telah diizinkan (SPLN 26). Untuk menentukan teganagan sentuh dan tegangan langkah diperlukan Metode Grounding Grid. Hasil simulasi penggunaan NGR (Neutral Grounding Resistor) di PT PLN (Persero) Gardu Induk Sukorejo Pasuruaan dapat mereduksi arus hubung singkat dengan nilai Reistance NGR pada sisi primer sebesar 163,30 Ω dan sisi sekunder 46,66 Ω dengan demikian arus gangguan hubung singkat dapat direduksi berkisar 247 A sehingga tidak melebihi batas aman yang diizinkan dan tegangan sentuh pada Bus 4 dapat diperoleh sebesar 162,3 V dan pada Bus 5 sebesar 162,3 V, sedangkan tegangan langkah pada Bus 4 dapat diperoleh sebesar 167,3 V dan pada Bus 5 sebesar 167,5 V sehingga tidak membahayakan bagi makluk hidup yang berada pada area Gardu Induk. Kata Kunci : NGR (Nutral Grounding Resistor), grounding grid, tegangan sentuh dan tegangan langkah, transformator. iv Analysis Of NGR ( Neutral Grounding Resistor ) On The Substation’s Transformator To Reduce The Current Ground Fault At The Sukorejo Pasuruan Substation Moch Ajie Riszaldi I Made Wartana majieriszaldi@gmail.com Abstract The high current short circuit fault can endanger the transformer and living creature in the substation area, therefore NGR (Neutral Grounding Resistor) is needed to reduce short circuit current so that the touch voltage and step voltage do not exceed the permitted limit in accordance with IEEE 80 2000 standard. With the method of using NGR (Neutral Grounding Resistor) grounding system, one phase to ground short circuit current, two phase ground and three phase current can be reduced by determining the resistance value of NGR, so that the fault current does not exceed the permitted standard (SPLN 26). To determine the touch parameters and step voltage required Grounding Grid Method. Simulation results of the use of NGR (Neutral Grounding Resistors) at PT PLN (Persero) Sukorejo Substation Pasuruaan can reduce short circuit current with NGR Reistance value on the primary side of 163.30 Ω and secondary side 46.66 demikian thus the short circuit fault current can reduced to 247 A so that it does not exceed the permitted safe limit and the touch voltage on Bus 4 can be obtained at 162.3 V and on Bus 5 is 162.3 V, while the voltage step on Bus 4 can be obtained at 167.3 V and on the Bus 5 is 167.5 V so that it does not endanger living beings in the area of the Substation. to determine the touch parameters and step voltage required Grounding Grid Method Keyword : NGR (Nutral Grounding Resistor), grid grounding, touch voltage and step voltage, transformer

Item Type: Thesis (Skripsi)
Uncontrolled Keywords: NGR (Nutral Grounding Resistor), grid grounding, touch voltage and step voltage, transformer
Subjects: Engineering > Electrical Engineering
Divisions: Fakultas Teknologi Industri > Teknik Elektro S1 > Teknik Elektro S1(Skripsi)
Depositing User: Ms Nunuk Yuli
Date Deposited: 18 Feb 2019 04:28
Last Modified: 13 Mar 2019 06:22
URI: http://eprints.itn.ac.id/id/eprint/2000

Actions (login required)

View Item View Item