Ibrahim, M. Malik (2017) ANALISIS ZERO SEQUENCE BLOCKING TRANSFORMATOR (ZSBT) UNTUK MENGURANGI ARUS GROUND FAULT PADA JARINGAN DISTRIBUSI 20 KV KABUPATEN LOMBOK TENGAH. Skripsi thesis, Institut Teknologi Nasional Malang.
Text
ANALISIS ZERO SEQUENCE BLOCKING TRANSFORMATOR II.pdf Restricted to Registered users only Available under License Creative Commons Attribution Non-commercial Share Alike. Download (3MB) | Request a copy |
Abstract
ABSTRAK ANALISIS ZERO SEQUENCE BLOCKING TRANSFORMATOR (ZSBT) UNTUK MENGURANGI ARUS GROUND FAULT PADA JARINGAN DISTRIBUSI 20 KV KABUPATEN LOMBOK TENGAH M. Malik Ibrahim, NIM 1312013 Dosen Pembimbing I : Ir. Teguh Herbasuki, MT Dosen Pembimbing II : Ir. Ni Putu Agustini,MT Pada sistem tenaga listrik, sistem distribusi berperan untuk menyalurkan daya listrik dari sumber daya listrik yang bertegangan tinggi hingga ke saluran tegangan menengah hingga sampai ke beban atau konsumen. Sistem distribusi berperan penting dalam menyalurkan daya ke beban. Saat ini yang harus di perhatikan di lombok tengah adalah di jaringan 20 kv dengan melihat permasalahan yang ada pada jaringan 20 kv yaitu seringnya pemadaman bergilir karena adanya gangguan eksternal seperti pohon tumbang dan sambaran petir sedangkan gangguan internalnya karena gagalnya peralatan proteksi dalam mengamankan sistem itu sendiri, oleh sebab itu sistem proteksi memiliki peran penting agar sistem bekerja dengan optimal. dengan di netralkan nilai arus oleh Zero Sequence Bloking Transformator (ZSBT), oleh sebab itu ZSBT ini harus dapat mengurangi arus pada sisi netral transformatornya dengan memblocking arus agar tidak menimbulkkan harmonisa yang di peralatan tersebut. Pada penelitian ini penulis menggunakan metode Zero Sequence Blocking Transformator untuk mengurangi arus ground fault pada Transformator Gardu Induk mantang kapasitas 150 kV 20 kV 30 MVA. Sistem Zero Sequence Blocking Transformator (ZSBT) dapat mengurangi arus ground fault pada sisi netral Transformator dari nilai arus yang paling tinggi 8.715174 ampere dan setelah di terapkan ZSBT yang memblocking arus turun menjadi 2.043253 ampere yang sangat bagus di terapkan di gardu induk mantang. Kata kunci : Transformator, Arus ground Fault, ZSBT iii ABSTRACT ANALISIS ZERO SEQUENCE BLOCKING TRANSFORMATOR (ZSBT) UNTUK MENGURANGI ARUS GROUND FAULT PADA JARINGAN DISTRIBUSI 20 KV KABUPATEN LOMBOK TENGAH M. Malik Ibrahim, NIM 1312013 Lecturer I : Ir. Teguh Herbasuki, MT Lecturer II : Ir. Ni Putu Agustini,MT In electric power systems, the distribution system plays a role to channel power from high voltage power sources down to medium voltage lines to the load or the consumer. The distribution system plays an important role in channeling power to the load. Currently that should be noted in central lombok is in 20 kv network by looking at existing problems on 20 kv network that is often the rotating blackouts due to external disturbances such as fallen trees and lightning strikes while the internal disturbance due to failure of protection equipment in securing the system itself, Therefore the protection system has an important role for the system to work optimally. Therefore the protection system has an important role for the system to work optimally. With neutralized current value by Zero Sequence Bloking Transformator (ZSBT), Therefore this ZSBT should be able to reduce the current on the neutral side of the transformer by blocking the current so as not to cause the harmonics in the equipment. In this study the authors use the method Zero Sequence Blocking Transformer to reduce ground fault current on Transformer Substation feeder capacity of 150 kV 20 kV 30 MVA. The Zero Sequence Blocking Transformer (ZSBT) system can reduce ground fault current on the neutral side of the Transformer from the highest current rating of 8.715174 amperes and after the applied ZSBT which blocks the down current to 2.043253 amperes which is very good applied in the mover substation. Keywords: Transformator, Current Ground Fault, ZSBT
Item Type: | Thesis (Skripsi) |
---|---|
Uncontrolled Keywords: | Transformator, Current Ground Fault, ZSBT |
Subjects: | Engineering > Electrical Engineering |
Divisions: | Fakultas Teknologi Industri > Teknik Elektro S1 > Teknik Elektro S1(Skripsi) |
Depositing User: | Ms Nunuk Yuli |
Date Deposited: | 18 Jul 2019 03:44 |
Last Modified: | 18 Jul 2019 03:44 |
URI: | http://eprints.itn.ac.id/id/eprint/3613 |
Actions (login required)
View Item |