ABSTRAK ANALISIS KEMAMPUAN PENTANAHAN MENARA SUTT TERHADAP SAMBARAN PETIR LANGSUNG YANG MENGAKIBATKAN BACKFLASHOVER PADA SALURAN TRANSMISI 150 KV PONOROGO – MANISREJO Yoppi Kurnia Putra, NIM: 13.12.012 Dosen pembimbing : Dr. Eng. Ir. I Made Wartana, MT. dan Ir. Teguh Herbasuki, MT Jurusan Teknik Elektro S-1, Konsentrasi Teknik Energi Listrik Fakultas Teknologi Ingustri, Institut Teknologi Nasional Malang Email : yoppikurniaputra@gmail.com Saluran transmisi merupakan saluran untuk menyalurkan energi listrik dari pembangkit ke konsumen. Lokasi menara saluran transmisi pada suatu daerah tertentu sangat menentukan banyaknya gangguan yang terjadi akibat sambaran petir. Besar sambaran petir langsung pada menara atau kawat tanah dapat mengakibatkan back flashover pada isolator. Besarnya arus sambaran petir dan besarnya nilai resistansi pentanahan menara dapat mempengaruhi besarnya tegangan gangguan yang terjadi. Pada skripsi ini untuk mengurangi besar dampak tegangan gangguan yaitu dengan memperkecil nilai pentanahan menara. Dengan menambah panjang elektroda pentanahan dapat memperkecil nilai pentanahan menara. Dan dengan program PSCAD dapat mengetahui besar lonjakan gelombang sebelum dan sesudah merubah nilai resistansi menara. Arus sambaran petir 180 kA dapat mengakibatkan backflashover, karena nilai tegangan crossarm melebihi tegangan lompatan api yaitu sebesar 1324,31 kV sedangkan batas tegangan lompatan api sebesar 1315,46 kV pada kondisi pentanahan menara 2,24 Ω. Dengan penambah panjang elektroda sepanjang 20 meter hasil nilai pentanahan menara sebesar 0,84 Ω. Sehingga dapat menurunkan tegangan pada crossarm menjadi 1292,25 kV. Kata kunci: Sambaran petir langsung, backflashover, resistansi pentanahan menara, PSCAD. iii ABSTRACT THE ANALYSIS OF SUTT TOWER RESISTANCE CAPABILITY TO DIRECT LIGHTNING STRIKE RESULTING IN BACKFLASHOVER ON THE 150 KV TRANSMISSION LINE IN PONOROGO-MANISREJO Yoppi Kurnia Putra, NIM: 13.12.012 Supervisiors : Dr. Eng. Ir. I Made Wartana, MT. dan Ir. Teguh Herbasuki, MT Electrical Engineering Major S-1, The Concentration of Electrical Energy Techniques Industrial Technology Faculty, National Institute Technology Malang Email : yoppikurniaputra@gmail.com Transmission line is a distribution line for electrical energy from generator to consumer. The location of the transmission line towers in a particular area greatly determine the number of disturbances that occur due to the lighting strike. A large direct lighting strike on the tower or ground wire can lead to backflasover on the insulator. The amount of lighting strike current and the magnitude of the tower grounding resistance value can affect the magnitude of the disturbance voltage that occurs. This thesis explains the way to reduce the magnitude of the impact of voltage disturbance by reducing the value tower resistance. Increasing the length of the earth electrode can reduce the value of the tower resistance. The 180 kA lighting current result in a backflashover, because the value of crossarm voltage exceeds fire jump voltage that is equal to 1324,31 kV, while the limit of fire jump is equal to 1315,46 kV on the grounding tower. With the addition of 20 meters long electrode of the tower grounding value of 0,84 Ohm. So, it can reduce voltage at crossarm to be 1292,25 kV. Keywords : Direct lightning strike, backflashover,tower grounding resistance.

Item Type: Thesis (Skripsi)
Additional Information: Yoppi Kurnia Putra, NIM: 13.12.012
Uncontrolled Keywords: Sambaran petir langsung, backflashover, resistansi pentanahan menara, PSCAD.
Subjects: Engineering > Electrical Engineering
Divisions: Fakultas Teknologi Industri > Teknik Elektro S1 > Teknik Elektro S1(Skripsi)
Depositing User: Ms Nunuk Yuli
Date Deposited: 28 Aug 2019 06:22
Last Modified: 28 Aug 2019 06:22
URI: http://eprints.itn.ac.id/id/eprint/4068

Actions (login required)

View Item View Item