IMPLEMENTASI PENGGUNAAN SISTEM GROUNDING GENERATOR MENGGUNAKAN NGR (NEUTRAL GROUNDING RESISTANCE) UNTUK MEREDUKSI ARUS GANGGUAN 1 FASA KE TANAH PADA PLTD BALIKPAPAN

Prayitno, Hendra Dwi (2017) IMPLEMENTASI PENGGUNAAN SISTEM GROUNDING GENERATOR MENGGUNAKAN NGR (NEUTRAL GROUNDING RESISTANCE) UNTUK MEREDUKSI ARUS GANGGUAN 1 FASA KE TANAH PADA PLTD BALIKPAPAN. Skripsi thesis, Institut Teknologi Nasional Malang.

[img] Text
SKRIPSI PDF HENDRA.pdf
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (3MB)

Abstract

ABSTRAK IMPLEMENTASI PENGGUNAAN SISTEM GROUNDING GENERATOR MENGGUNAKAN NGR (NEUTRAL GROUNDING RESISTOR)UNTUK MEREDUKSI ARUS GANGGUAN 1 FASA KE TANAH PADA PLTD BALIKPAPAN Hendra Dwi Prayitno, NIM: 1312017 Dosen Pembimbing I : Ir.Teguh Herbasuki, MT Dosen Pembimbing I : Ir.Taufik Hidayat, MT Gangguan arus hubung singkat (1 phasa ketanah) pada generator yang tinggi dapat menggakibatkan generator terganggu dan berbahaya dengan sistem pentanahan(solid) grounding yang masih digunakan pada PLTD Gunung Malang Balikpapan terlihat dari hasil simulasi ETAP sebesar 6,62 KA untuk generator 1-2 (siemens) dan 6,66 KA untuk generator 3-6 (smith) dengan hasil tersebut gangguan arus hubung singkat(1 phasa ketanah) bisa mengakibatkan busur listrik(arcfault) yang dapat mengakibatkan terbakarnya stator pada generator dan sangat berbahaya bagi generator dengan melakukan pergantian sistem pentanahan menggunakan NGR(neutral grounding resistance) arus gangguan hubung singkat (1 phasa ke tanah) dapat di reduksi dengan nilai resistance sebesar 7,94 Ω untuk generator 1-2 (siemens) dan 7,21 Ω untuk generator 3-6 (smith) sehingga arus gangguan hubung singkat (1 phasa ketanah)berkisar 454 A untuk generator 1-2(siemens) dan 499 A untuk generator 3-6(smith)maka dari itu pergantian sistem pentanahan menggunakan NGR(neutral grounding resistance) sangat di perlukan untuk dapat menanggulangi jika terjadi arus gangguan hubung singkat(1 phasa ke tanah) yang begitu besar yang bisa kapan saja terjadi dan membahayakan bagi lingkungan sekitar dan generator. Kata kunci : (solid) grounding,NGR(neutral grounding resistance),generator iii THE IMPLEMENTATION OF GENERATOR GROUNDING SYSTEM USING NGR (NEUTRAL GROUNDING RESISTORS) TO REDUCE SINGLE PHASE TO GROUND FAULT AT DIESEL POWER PLANT IN BALIKPAPAN Hendra Dwi Prayitno Lecturer I : Ir.Teguh Herbasuki, MT Lecturer II : Ir.Taufik Hidayat, MT Departement Of Electrical Enginering S-1, Concentration Of Electrical Energy The Faculty Industrial Technology, National Institute Of Technolgy Malang Jl. Raya Karanglo Km 2 Malang E-mail : hendradprayitno@gmail.com Single phase to ground fault on a high generator could interfere with the generator work and cause danger especially on an effective grounding system (solid) used in Gunung Malang Diesel Power Plant, Balikpapan. This could be seen from the results of ETAP simulation, i.e., 6.62 KA for generator 1-2 (Siemens) and 6.66 KA for generator 3-6 (Smith). Based on these results, it could be concluded that single phase to ground fault might result in the occurrence of arcfault which would cause the stator on the generator to burn and thus, it might damage the generator. By changing the grounding system using NGR (neutral grounding resistance), the single phase to ground fault can be reduced with the resistance value of 7.94 Ω for generator 1-2 (Siemens) and 7.21 Ω for generator 3-6 (Smith). Thus, the value of single phase to ground fault obtained was around 454 A for generator 1-2 (Siemens) and 499 A for generator 3-6 (Smith). Therefore, the changing of grounding system using NGR (neutral grounding resistance) was greatly needed to help overcoming the problem faced when large single phase to ground fault occurred, since this single phase to ground fault could occur at any time and might damage the environment and generator. Keywords :(solid) grounding,NGR(neutral grounding resistance),generator

Item Type: Thesis (Skripsi)
Additional Information: Hendra Dwi Prayitno, NIM: 1312017
Uncontrolled Keywords: solid) grounding,NGR(neutral grounding resistance),generator
Subjects: Engineering > Electrical Engineering
Divisions: Fakultas Teknologi Industri > Teknik Elektro S1 > Teknik Elektro S1(Skripsi)
Depositing User: Ms Nunuk Yuli
Date Deposited: 28 Aug 2019 05:05
Last Modified: 28 Aug 2019 05:05
URI: http://eprints.itn.ac.id/id/eprint/4055