Analisis Over Currant Relay (OCR) Pada Jaringan Distribusi Akibat Injeksi Pembangkit Listrik Tenaga Surya Di Gedung Teknik Elektro ITN

Praduta, Randa (2018) Analisis Over Currant Relay (OCR) Pada Jaringan Distribusi Akibat Injeksi Pembangkit Listrik Tenaga Surya Di Gedung Teknik Elektro ITN. Skripsi thesis, Institut Teknologi Nasional.

[img] Text
16. File Lengkap Skripsi.pdf
Restricted to Registered users only
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (4MB) | Request a copy

Abstract

Analisis Over Currant Relay (OCR) Pada Jaringan Distribusi Akibat Injeksi Pembangkit Listrik Tenaga Surya Di Gedung Teknik Elektro ITN Malang Randa Praduta Abraham Lomi randapraduta@gmail.com ABSTRAK Sistem tenang listrik dalam suatu jaringan sangat tergantung kepada sistem pengaman yang digunakan, oleh sebab itu dalam suatu sistem tenaga listrik perlu diperhatikan kondisi-kondisi gangguan yang akan terjadi salah satuanya adalah gangguan hubung singkat, gangguan hubung singkat ini merupakan gangguan yang sering terjadi , baik itu gangguan di sisi satu fasa ke tanah dua fasa ke tanah antar fasa. Penelitian ini akan menganalisis Over Current Relay ( OCR ) pada jaringan distribusi akibat interkoneksi pada pembangkit tenaga surya (PLTS) di gedung elektro ITN Malang yang dimana OCR atau relay arus lebih adalah suatu relai yang bekerjanya berdasarkan adanya kenaikan arus yang melebihi suatu nilai pengaman tertentu dalam jangka waktu tertentu, sehingga relai ini dapat dipakai sebagai pola pengaman arus lebih. Over Current Relay ( OCR ) ini berfungsi untuk memproteksi Sistem Pembangkit Listrik Tenaga Surya terhadap arus lebih yang disebabkan oleh gangguan arus hubung singkat. Analisa dan simulasi menggunakan Software ETAP Power Station v.12.6.0 Kata Kunci : Over Currant Relay (OCR), Hubung Singkat, Pembangkit Tenaga Surya (PLTS). Analysis Over Currant Relay (OCR) In Distribution Network Due To Injection Of Solar Power Generating Stations In Building Electrical Engineering ITN Malang Randa Praduta Abraham Lomi randapraduta@gmail. ABSTRACT The quiet system of electricity in a network is very dependent on the safety system used, therefore in an electric power system it is necessary to pay attention to the conditions of disturbance that will occur, one of which is a short circuit, this short circuit is a frequent disorder, both interference on one phase side to two phase ground to ground between phases. This study will analyze Over Current Relay (OCR) on the distribution network due to interconnection in solar power plants (PLTS) in the ITN Malang electrical building where OCR or overcurrent relay is a relay that works based on the current increase that exceeds a certain safety value in a certain period of time, so that this relay can be used as a safety pattern for overcurrent. Over Current Relay (OCR) serves to protect the Solar Power System against overcurrent caused by a short circuit current. Analysis and simulation using ETAP Power Station Software v.12.6.0 Keywords : Over Currant Relay (OCR), Short Circuit, Solar Power Plant (PLTS).

Item Type: Thesis (Skripsi)
Uncontrolled Keywords: Over Currant Relay (OCR), Hubung Singkat, Pembangkit Tenaga Surya (PLTS).
Subjects: Engineering > Electrical Engineering
Divisions: Fakultas Teknologi Industri > Teknik Elektro S1 > Teknik Elektro S1(Skripsi)
Depositing User: Ms Nunuk Yuli
Date Deposited: 09 Jan 2019 08:19
Last Modified: 13 Mar 2019 06:19
URI: http://eprints.itn.ac.id/id/eprint/135