IMPLEMENTASI DYNAMIC VOLTAGE RESTORER(DVR) UNTUK MENGURANGI TEGANGAN SAG AKIBAT PENGASUTAN MOTOR INDUKSI DI PT. SUMBER ABADI BERSAMA

Sukmawan, Hery (2018) IMPLEMENTASI DYNAMIC VOLTAGE RESTORER(DVR) UNTUK MENGURANGI TEGANGAN SAG AKIBAT PENGASUTAN MOTOR INDUKSI DI PT. SUMBER ABADI BERSAMA. Skripsi thesis, Institut Teknologi Nasional Malang.

[img] Text
File Lengkap Skripsi.pdf
Restricted to Registered users only
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (2MB) | Request a copy

Abstract

IMPLEMENTASI DYNAMIC VOLTAGE RESTORER (DVR) UNTUK MENGURANGI TEGANGAN SAG AKIBAT PENGASUTAN MOTOR INDUKSI DI PT. SUMBER ABADI BERSAMA Hery Sukmawan Abraham Lomi herysukmawan@gmail.com ABSTRAK Berdasarkan IEEE Standard 1159-1995 voltage sag merupakan sebuah gejala penurunan tegangan antara 0.1 sampai 0.9 pu selama durasi waktu dari 0.5 cycles hingga 1 menit, dan salah satu penyebabnya adalah akibat pengasutan motor (motor starting). Motor listrik AC (sangkar tupai dan sinkron) menarik arus awal sebesar 5– 6 kali arus nominal beban penuh agar dapat memperoleh torsi starting atau pengasutan cukup untuk mulai berputar. Adanya arus awal besar yang secara tiba-tiba ditarik dari sistem tenaga listrik tersebut dapat menyebabkan voltage sag sesaat. Voltage sag yang terjadi pada sistem tenaga tersebut akan mempengaruhi kualitas kerja peralatan elektronik seperti sensor – sensor atau rangkaian kontrol yang mempunyai sensitivitas yang tinggi akan perubahan tegangan. Pada penelitian ini membahas implementasi Dinamic Voltage Restorer (DVR) untuk mengurangi tegangan sag akibat pengasutan motor induksi di PT.Sumber Abadi Bersama (PT.SAB). Pemodelan dan simulasi DVR akan dilakukan menggunakan software PSCAD 4.5. Bagian dari rancangan DVR berupa Injection/coupling transformers, Voltage Source Converter (VSC) dan energy storage. Untuk komponen VSC atau komponen switching terdiri dari Insulated Gate Bipolar Transistors (IGBT) dan kontrol tegangan menggunakan teknik PI (Proposional Integral). Tujuannya penggunaan kendali PI adalah keefektifan dalam mengontrol steady state error pada sebuah sistem pengendali, selain itu pengendalian PI juga mudah diimplementasikan. Dari hasil simulasi kompensasi voltage sag menggunakan DVR pada sistem kelistrikan PT.SAB, mampu mengkompensasikan saat kondisi voltage sag sebesar 0.4548 p.u dan dengan hasil kompensasi DVR adalah 0.9176 p.u Kata kunci : Voltage sag, Dynamic Voltage Restore (DVR),Starting Motor, PI (Proposional Integral). iii IMPLEMENTATION OF DYNAMIC VOLTAGE RESTORER (DVR) TO REDUCE SAG VOLTAGE DUE TO INDUCTION OF INDUCTION MOTORS IN PT. SUMBER ABADI BERSAMA Hery Sukmawan Abraham Lomi herysukmawan@gmail.com ABSTRAK Under the IEEE Standard 1159-1995 voltage sag is a symptom of a decrease in voltage between 0.1 to 0.9 pu for a duration of time from 0.5 cycles to 1 minute, and one of the causes is due to motor starting. AC electric motors (squirrel cages and synchronous) draw the initial current 5–6 times the nominal current of the full load in order to get the starting torque or fixing enough to start spinning. The existence of large initial currents that are suddenly pulled from the electric power system can cause a momentary sag voltage. Voltage sag that occurs in the power system will affect the quality of work of electronic equipment such as sensors or control circuits that have a high sensitivity to voltage changes. In this study discusses the implementation of Dynamic Voltage Restorer (DVR) to reduce sag voltage due to induction motor induction at PT. Sumber Abadi Bersama (PT.SAB). DVR modeling and simulation will be carried out using PSCAD 4.5 software. Part of the DVR design in the form of Injection / coupling transformers, Voltage Source Converter (VSC) and energy storage. For VSC components or switching components consist of Insulated Gate Bipolar Transistors (IGBT) and voltage control using PI (Proposal Integral) techniques. The purpose of using PI control is the effectiveness in controlling the steady state error in a controller system, besides controlling PI is also easy to implement. From the results of sag voltage compensation simulation using DVR on PT.SAB electrical system, it is able to compensate when the sag voltage condition is 0.4548 p.u and with the DVR compensation result is 0.9176 p.u Keywords: Voltage sag, Dynamic Voltage Restore (DVR), Starting Motor, PI (Proposal Integral).

Item Type: Thesis (Skripsi)
Uncontrolled Keywords: Voltage sag, Dynamic Voltage Restore (DVR), Starting Motor, PI (Proposal Integral).
Subjects: Engineering > Electrical Engineering
Divisions: Fakultas Teknologi Industri > Teknik Elektro S1 > Teknik Elektro S1(Skripsi)
Depositing User: Ms Nunuk Yuli
Date Deposited: 20 Feb 2019 04:38
Last Modified: 13 Mar 2019 06:37
URI: http://eprints.itn.ac.id/id/eprint/2162