Rekonfigurasi Sistem Distribusi 20 kv Untuk Meminimalkan Rugi Rugi Sistem Pada PT.PLN (Persero) Area Flores Bagian Barat Dengan Menggunakan Software Etap Jefrinus Lei Uta Ir. Yusuf Ismail Nakhoda, MT Ir. Teguh Herbasuki, MT jefrynus@gmail.com ABSTRAK Salah satu masalah yang terdapat dalam sistem distribusi adalah losses dan penurunan tegangan yang seringkali terjadi dalam penyaluran tenaga listrik. Untuk mengantisipasi agar tegangannya tetap konstan dan untuk memperkecil losses pada saluran distribusi maka perlu adanya rekonfigurasi jaringan. Pada sistem distribusi panjangnya saluran ke ujung penyulang seringkali terjadi drop tegangan dan rugi-rugi pada saluran. Untuk mengantisipasi hal semacam itu maka perlu adanya rekonfigurasi pada sistem distribusi agar tegangan yang dikirim ke konsumen tetap konstan dan losses berkurang. Dalam skripsi ini akan di bahas mengenai rekonfigurasi jaringan distribusi agar tegangan yang disalurkan ke beban tetap konstan. Dari analisa diperoleh bahwa dengan merubah tap pada transformator maka profil tegangan menjadi lebih baik atau berada pada standar yang di tetapkan PLN (0,95 < V < 1,05) dan setelah merekonfigurasi jaringan maka losses menjadi lebih kecil dari losses sebelumnya (sebelum rekonfigurasi MW=0.131, MVAR=0.288, MVA=0.674 setelah rekonfigurasi jaringan MW=0.108, MVAR=0.281, MVA=0.711) dan meningkatkan tegangan pada ujung pelayanan hingga ke batas-batas toleransi. Kata kunci : Rekonfigurasi, Losses, Tegangan, ETAP 20 KV Distribution System Configuration To Minimize System Loss In PT. PLN (Persero) West Flores Area Using Etap Software Jefrinus Lei Uta Ir. Yusuf Ismail Nakhoda, MT Ir. Teguh Herbasuki, MT jefrynus@gmail.com ABSTRACT One of problems found in the distribution system is a losses and a decrease in voltage that oftenoccur in the distribution of electrical power. For the anticipation so that tha loss in distribution channels it is necessary the presence of network configuration. On the distribution system in lenght to the group of chanels often happened fell voltage and loss on the channel. For the anticipation of that sort of thing then the existance of reconfiguration on distribution system so that the voltage sent to the consumer remains constant and the reduced loss. In this thesis will be discussed regarding the reconfiguration of distribution network so that the voltage transmitted to the load remains constant. From the analysis of the obtained that increase by changing the voltage on the transformer voltage profiles then become better or on a standard set in the PLN(0,95<V<1,05) and after the reconfiguration of the network then the loss is smaller than the previous loss. (before the roconfiguration MW= 0.313 Mvar = 0.288 MVA= 0.674 after a reconfiguration MW= 0.108 Mvar = 0.281 MVA= 0.711) and increase the voltage at the ends of the service up to the limits of tolerance. Keywords: Reconfiguration, Loss, Voltage, ETAP.

Item Type: Thesis (Skripsi)
Uncontrolled Keywords: Reconfiguration, Loss, Voltage, ETAP
Subjects: Engineering > Electrical Engineering
Divisions: Fakultas Teknologi Industri > Teknik Elektro S1 > Teknik Elektro S1(Skripsi)
Depositing User: Ms Nunuk Yuli
Date Deposited: 24 May 2019 03:30
Last Modified: 24 May 2019 03:30
URI: http://eprints.itn.ac.id/id/eprint/3550

Actions (login required)

View Item View Item