ANALISIS PROFIL TEGANGAN AKIBAT INTEGRASI PEMBANGKIT PV - KAPASITAS 5MW PADA JARINGAN DISTRIBUSI 20KV PLN KUPANG

DO Nacimento, Longginus L. (2022) ANALISIS PROFIL TEGANGAN AKIBAT INTEGRASI PEMBANGKIT PV - KAPASITAS 5MW PADA JARINGAN DISTRIBUSI 20KV PLN KUPANG. Skripsi thesis, ITN MALANG.

[img] Text
1612010_COVER.pdf

Download (765kB)
[img] Text
1612010_BAB I.pdf

Download (301kB)
[img] Text
1612010_BAB II.pdf

Download (503kB)
[img] Text
1612010_BAB III.pdf

Download (354kB)
[img] Text
1612010_BAB IV.pdf

Download (1MB)
[img] Text
1612010_BAB V.pdf

Download (289kB)
[img] Text
1612010_BAB VI.pdf

Download (363kB)
[img] Text
1612010_LAMPIRAN 1.pdf

Download (1MB)
[img] Text
1612010_LAMPIRAN 2.pdf

Download (630kB)

Abstract

DISTRIBUSI 20KV PLN KUPANG Longginus L. Do Nacimento, Abraham Lomi, Widodo Pudji Muljanto mentoyogi@gmail.com ABSTRAK Dalam penelitian ini akan membahas tentang dampak yang mungkin saja terjadi dari berbagai tingkat penetrasi pembangkit terdistribusi pada profile tegangan di jaringan distribusi tegangan menegah. Akibat dari kebutuhan energy listrik yang semakin meningkat, karena jaringan listrik semakin luas permintaan listrik pun semakin besar, serta jarak dari pusat pembangkit ke pusat beban akan menyebabkan pengurangan daya karena dalam pengiriman daya dari generator ke konsumen atau pelangan ada daya yang hilang dan drop tegangan.[1] Maka dari itu untuk mengatasinya, di gunakan generated distribution (DG) di jaringan distribusi. Fokus dari penelitian ini untuk melihat bagaimana pengaruh pemasangan DG pada system distribusi untuk meningkatkan profile tegangan dan mengurangi rugi –rugi daya pada jaringan distribusi tersebut.[2] Penelitian ini berlokasi di Kupang – NTT, pada pembangkit listirk tenaga surya PLTS (PV) yang berkapasitas 5 MW. Kata Kunci— profil tegangan, rugi-rugi daya, DG, PV-5MW. VOLTAGE PROFILE ANALYSIS DUE TO INTEGRATION OF 5MW PV-CAPACITY POWER PLANT ON 20KV PLN KUPANG DISTRIBUTION NETWORK Longginus L. Do Nacimento, Abraham Lomi, Widodo Pudji Muljanto mentoyogi@gmail.com ABSTRACK In this study, we will discuss the impact that may occur from various levels of penetration of distributed generators on the voltage profile in the medium voltage distribution network. As a result of the increasing demand for electrical energy, because the electricity network is wider, the demand for electricity is even greater, and the distance from the generating center to the load center will cause a reduction in power because in the delivery of power from the generator to consumers or customers there is power loss and voltage drop. [1] Therefore, to overcome this, a generated distribution (DG) is used in the distribution network. The focus of this study is to see how the effect of installing DG on the distribution system is to increase the voltage profile and reduce power losses in the distribution network.[2] This research is located in Kupang – NTT, at a PLTS (PV) solar power plant with a capacity of 5 MW. Keywords— voltage profile, power losses, DG, PV-5MW.

Item Type: Thesis (Skripsi)
Additional Information: Longginus L.Do Nacimento 1612010
Uncontrolled Keywords: Voltage profile, Power Loses, DG, PV-5MW
Subjects: Engineering > Electrical Engineering
Divisions: Fakultas Teknologi Industri > Teknik Elektro S1 > Teknik Elektro S1(Skripsi)
Depositing User: Users 488 not found.
Date Deposited: 28 Jul 2022 02:05
Last Modified: 28 Jul 2022 02:13
URI: http://eprints.itn.ac.id/id/eprint/8772